This work introduces an observer structure and highlights its distinct advantages in fault detection and isolation. Its application to the issue of shorted turns detection in synchronous generators is demonstrated. For the theoretical foundation, the convergence and design of Luenberger-type observers for disturbed linear time-invariant (LTI) single-input single-output (SISO) systems are reviewed with a particular focus on input and output disturbances. As an additional result, a simple observer design for stationary output disturbances that avoids a system order extension, as in classical results, is proposed.

[1] D.G.Luenberger .Observing the state of a linear system[J].IEEE Transactions on Military Electronics,1964,8(02):74-80.

[2] D.Luenberger .An introduction to observers[J].IEEE Transactions on Automatic Control,1971,16(06):596-602.

[3] S.Balemi.Partial-order reduction of observers for linear systems[A].Seoul,Korea:Elsevier,2008:7723-7728.

[4] R.J.Mil er;R.Mukundan .On designing reduced-order observers for linear time-invariant systems subject to unknown inputs[J].International Journal of Control,1982,35(01):183-188.

[5] Yang F.;Wilde R.W. .Observers for linear systems with unknown inputs[J].IEEE Transactions on Automatic Control,1988(7):677-681.

[6] Hou M.;Muller P.C. .Design of observers for linear systems with unknown inputs[J].IEEE Transactions on Automatic Control,1992(6):871-875.

[7] Hou M.;Muller P.C. .Disturbance decoupled observer design: a unified viewpoint[J].IEEE Transactions on Automatic Control,1994(6):1338-1341.

[8] M.Darouach;M.Zasadzinski;S.Xu .Ful-order observers for linear systems with unknown inputs[J].IEEE Transactions on Automatic Control,1994,39(03):606-609.

[9] M.Lungu;R.Lungu .Ful-order observer design for linear systems with unknown inputs[J].International Journal of Control,2012,85(10):1602-1615.

[10] A.Samantaray;B.Bouamama.Model-based Process Supervision:A Bond Graph Approach[A].Berlin:Springer-Verlag,2008

[11] J.Park;G.Rizzoni;W.B.Ribbens .On the representation of sensor faults in fault detection filters[J].AUTOMATICA,1994,30(11):1793-1795.

[12] Wang H.;Daley S. .Actuator fault diagnosis: an adaptive observer-based technique[J].IEEE Transactions on Automatic Control,1996(7):1073-1078.

[13] H. Hammouri;M. Kinnaert;E. H. El Yaagoubi .Observer-based approach to fault detection and isolation for nonlinear systems[J].IEEE Transactions on Automatic Control,1999(10):1879-1884.

[14] Gao Z.;Breikin T.;Wang H. .High-Gain Estimator and Fault-Tolerant Design With Application to a Gas Turbine Dynamic System[J].IEEE transactions on control systems technology: A publication of the IEEE Control Systems Society,2007(4):740-753.

[15] Park JK.;Shin DR.;Chung TM. .Dynamic observers for linear time-invariant systems[J].Automatica,2002(6):1083-1087.

[16] A.Wahrburg;J.Adamy.Robust fault isolation using dynamical y extended observers[A].Dubrovnik,Croatia:IEEE,2012:1201-1206.

[17] Min WU,Kunpeng LOU,Fangchun XIAO,Ruijuan LIU,Yong HE,Jinhua SHE.Design of equivalent-input-disturbance estimator using a generalized state observer[J].控制理论与应用(英文版),2013(01):74-79.

[18] K.Emami;B.Nener;V.Sreeram.A fault detection technique for dynamical systems[A].Peradeniya,Sri Lanka:IEEE,2013:201-206.

[19] A Survey of Fault Detection, Isolation, and Reconfiguration Methods[J].IEEE transactions on control systems technology: A publication of the IEEE Control Systems Society,2010(3):636.

[20] T.Sel ami;H.Berriri;S.Jelassi.Sliding mode observer-based fault-detection of inter-turn short-circuit in induction motor[A].Sousse,Tunisia:IEEE,2013:524-529.

[21] Shao, S.;Wheeler, P.W.;Clare, J.C.;Watson, A.J. .Fault Detection for Modular Multilevel Converters Based on Sliding Mode Observer[J].IEEE Transactions on Power Electronics,2013(11):4867-4872.

[22] K.Zhang;B.Jiang;P.Shi.Observer-based Fault Estimation and Accomodation for Dynamic Systems[A].Berlin:Springer-Verlag,2012

[23] W.Chen;F.N.Chowdhury;A.Djuric et al.Robust fault detection of turbofan engines subject to adaptive control ers via a total measurable fault information residual(ToMFIR)technique[J].ISA Transactions,2014,53(05):1383-1388.

[24] F.Chowdhury;W.Chen.A modified approach to observer-based fault detection[A].Singapore:IEEE,2007:539-543.

[25] R.Fiser;D.Makuc;H.Lavric.Modeling,analysis and detection of rotor field winding faults in synchronous generators[A].Rome,Italy:IEEE,2010

[26] A Novel Rotor Ground-Fault-Detection Technique for Synchronous Machines With Static Excitation[J].IEEE Transactions on Energy Conversion,2010(4):p.965.

[27] T.Batzel.Observer-based monitoring of synchronous generator winding health[A].Atlanta:IEEE,2006:1150-1155.

[28] Amirnaser Yazdani;Reza Iravani .A Neutral-Point Clamped Converter System for Direct-Drive Variable-Speed Wind Power Unit[J].IEEE Transactions on Energy Conversion,2006(2):596-607.

[29] K.Malekian;A.Shirvani;U.Schmidt.Detailed modeling of wind power plants incorporating variable-speed synchronous generator[A].Montreal:IEEE,2009

[30] On Power Quality of Variable-Speed Constant-Frequency Aircraft Electric Power Systems[J].IEEE Transactions on Power Delivery,2010(1):55.

[31] I.Moir;A.Seabridge.Design and Development of Aircraft Systems[M].Chichester:John Wiley&Sons,2012

[32] Biagini, V.;Zanchetta, P.;Odavic, M.;Sumner, M.;Degano, M. .Control and Modulation of a Multilevel Active Filtering Solution for Variable-Speed Constant-Frequency More-Electric Aircraft Grids[J].IEEE transactions on industrial informatics,2013(2):600-608.

[33] J.Ackermann.Sampled-data Control Systems[M].Berlin:Springer-Verlag,1985

[34] R.E.Kalman .A new approach to linear filtering and prediction problems[J].Transactions of the ASME-Journal of Basic Engineering,1960,82:35-45.

[35] M.Darouach .Complements to ful order observer design for linear systems with unknown inputs[J].Applied Mathematics Letters,2009,22(07):1107-1111.

[36] S.Hui;S.Zak.Low-order unknown input observers[A].New York:IEEE,2005:4192-4197.

[37] R.J.Patton;P.M.Frank;R.N.Clarke.Fault Diagnosis in Dynamic Systems:Theory and Application[M].Upper Saddle River:Prentice-Hal,1989

[38] J.J.Gertler.Fault Detection and Diagnosis in Engineering Systems[M].Boca Raton:CRC Press,1998

[39] T.Wu;T.Camarano;J.Zumberge.Electromagnetic Design of Aircraft Synchronous Generator with High Power Density[M].Nashvil e:American Institute of Aeronautics and Astronautics,2012

[40] T.Lipo.Analysis of Synchronous Machines[M].Boca Raton:CRC Press,2012

[41] M.Eremia;M.Shahidehpour.Handbook of Electrical Power System Dynamics:Modeling,Stability,and Control.ser[A].Hoboken:John Wiley&Sons,2013

[42] J.Machowski;J.Bialek;J.Bumby.Power System Dynamics and Stability[M].Hoboken:John Wiley&Sons,1997


DOI: http://dx.doi.org/10.1007/s11768-014-3036-z

语种: 英文   


期刊热词
  • + 更多
  • 字体大小